Skip to main content

Insulation kits

Click to enlarge

Straight insulation sleeve kit

Watertight HDPE buried insulation kit for straight  extensions of single, double or quadruple pre-insulated pipes. Comes complete with mineral wool insulation, shrink sleeves and installation instructions.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Insulation sleeve
dout [mm]
Insulation sleeve
Length [mm]
Weight
[kg]
SIS90/75 90/75 110 600 1.8
SIS110 110 125 600 1.9
SIS140 140 160 850 3.0
SIS160 160 180 1000 4.0
SIS200 200 225 1000 6.0
SIS225 225 250 1000 7.3

Click to enlarge

T-insulation kit

Watertight HDPE buried insulation kit for T-junctions between single, double or quadruple pre-insulated pipes. Comes complete with mineral wool insulation, sealing compound, stainless steel bolts and plates and installation instructions.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Length
[mm]
Width
[mm]
Height
[mm]
Weight
[kg]
TIK140/90 140/110/90 1250 755 206 5.5
TIK225/140 225/200/160/140 1640 990 290 9.0

Click to enlarge

H-insulation kit

Watertight HDPE buried insulation kit for double T-junctions between single, double or quadruple pre-insulated pipes. Comes complete with mineral wool insulation, sealing compound, stainless steel bolts and plates and installation instructions.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Length
[mm]
Width
[mm]
Height
[mm]
Weight
[kg]
HIK225/140
225/200/160/140
2x MAIN
225/200/160/140
1x BRANCH 200/160/140
1640 1250 476 15.0

Click to enlarge

L-insulation kit

Watertight HDPE buried insulation kit for 90° L-junctions between single, double or quadruple pre-insulated pipes. Comes complete with mineral wool insulation, sealing compound, stainless steel bolts and plates and installation instructions.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Length
[mm]
Width
[mm]
Height
[mm]
Weight
[kg]
LIK225/140
225/200/160/140
990 990 290 7.5

Click to enlarge

Reducing adaptor sets for insulation kits

Reducing adapters are used to acco-modate smaller pipe diameters in larger insulation kit inlets. The reducing adapter is pressed into the insulation kit, and the transition between the adapter and the pre-insulated pipe is sealed with the heat shrink end cap, included in the set.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Weight
[kg]
RAS200/75 200 to 75 reduction 2.0
RAS200/90 200 to 90 reduction 2.5
RAS200/110 200 to 110 reduction 3.0

Click to enlarge

Underground inspection chamber

Underground inspection chamber with 6 possible inlets for the connection of single, double or quadruple pipes, allowing the integration of shut-off valves. Comes complete with lid, sealing compound, stainless steel bolts and installation instructions.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Length
[mm]
Width
[mm]
Height
[mm]
Weight
[kg]
UIC225/140 225/200/160/140 1570 1360 700 55.0

Click to enlarge

Shrink sleeve for underground inspection chamber

To obtain a leak-tight sealing between the inlets of the underground inspection chamber and the entering pre-insulated pipes, the appropriate shrink sleeves must be ordered separately.

Datasheet
Art. No.
Jacket pipe
dout [mm]
Length
[mm]
Weight
[kg]
SSL110/125 110 225 0.2
SSL160/180 140 225 0.3
SSL160/180 160 225 0.3
SSL225/250 200 225 0.4
SSL225/250 225 225 0.4

Terrendis is a subsidiary of the Elydan group. We design and manufacture high-performance and sustainable products with a virtuous life cycle for the environment. Our products contribute to improving the performance of tomorrow's networks infrastructure and buildings. Their environmental footprint is positive for the ecosystem.